Application

The Autoclave operates with saturated steam as the sterilization agent, working at pressure in the range of 0-32 p.s.i. (2.2 kg) and temperature in the range of 105`C to 137` C. Special temperature setting are available on request. The sterilization method substantially shortens the sterilization cycle,achieved by evacuating the air with a powerful ejector / vacuum pump,combined with steam pulsing.A 0.2 micron sterile air filter is provided to filter the air, which equalize the vessel pressure after the drying cycle. `MODIS`offers a large range of Sterilizer models from Standard 200 liter to 2000 liter size, as well as varied chamber dimensions according to the specific use and nature of Product requirements.

Standards

The sterilizers are manufactured as per I.S.I codes and bearing I.S.I Mark No. IS: 3829, Part-I & II endorsing the highest quality.

Centralised Control Point

  • Multi-port operating value : control for the entire cycle of the operating.
  • Permits two exhaust speeds,fast & slow.
  • Easy to read pressure & temperature.
  • Smooth operation.

Safety Features

  • Self locking safety door cannot be opened while chamber is under pressure.
  • Gauge glass tube with automatic closing safety valve.
  • Heat resistant SILICONE door gasket.
  • Pressure switched (on electric models) economise power consumption.
  • Low water protection system, to protect the electric heaters.
  • Temperature gauge / Digital temp.Indicators / controllers (optional)
  • Vacuum breaker / dryer.
  • Safety valve for the jacket / boiler.
  • Hydraulically test to 2.5 times the designed working pressure.
  • Powerful ejector for drying.
  • Insulated with resin bond fibre glass wool covered with M.S./S.S. sheet.
  • Heating: Direct steam, Electric OR LPG operated steam generators.
  • Fully automatic operation through a MICROSTER PROCESS.
  • Digital display temp. For semi-automatic operation.
  • Cycle with pre-vacuum option.
  • Thermograph to record temperature and time.
  • Double door type models.
  • Stainless Steel flush mounting.
  • Carriages,trolleys,baskets etc.for easy movement of goods.
  • Direct Steam: 1.2 kg/ cm pressure OR 2.1 KG/CM FOR High Speed Models.
  • Electricity: 3 Phase 440V, 50Hz AC supply.

For a clear and concise documentation of cycle process the control unit is provided with a dot matrix printer which is connected to the microprocessor .The printer generates a hard copy printout of the relevant information concerning the cycle operation such as the temperature, pressure. Vacuum, sterilization and drying time, number of cycles/number of pulsing etc. Incase of an uncompleted cycle,the printout indicates the cycle failure and the cause of the failure (optional) .An additional graphic printer is optional.

The sterilizer is designed to operator up to (6) six standard sterilization programs between 105 C and 137 C and (2) two test programs optional .All programs are selected by using the numeric keypad, and all programs are programmable. Air removal,sterilization and drying stages can be reprogrammed easily.

Table specification for Cylindrical sterilizer

Model MEC 15 MEC 24 MEC 36 MEC 48 MEC 45 MEC 54 MEC 60 MEC 72 MEC 90
Chamber DIA
mm / (inches)
DIA 300(12) 400(16) 400(16) 400(16) 500(20) 600(24) 500(20) 600(24) 750(30)
DEP 500(20) 600 (24) 900(36) 1200(48) 900(36) 900(36) 1200(48) 1200(48) 1200(48)
Chamber Vol. Lit. 35 75 113 151 177 254 235 339 3610
Floor space WID 1300 1400 1400 1400 1500 1600 1500 1600 1750
DEP 1400 1500 1800 2100 1800 1800 2100 2100 2100

Utilities Consumption / Requirements

Power 6kw 9kw 9kw 9kw 9kw 18kw 18kw 18kw
Boiler (Lit.) 45 69 44 44 44 44 44 80
Electrical requirements 42A 73A 24A 24A 24A 24A 24A 73A
Phase 3 3 3 3 3 3 3 3
(For automisation) Compressed air requirements: 3/8” thread connection